#railwayengineering
#SurgeArresters
=============== Specification 42 KV Gapless Lighting Arrester For WAP-5,WAP-7 & WAG-9 BY CLW===========
In this Particular BLOG I have shared the DRAWINGS made by CLW Engineers for Updated Specification of 42 KILOVOLT(KV) GAPLESS LIGHTING ARRESTER For 3-Phase Locomotives WAP-5,WAP-7 & WAG-9(Vide Specn. No. CLW/ES/3/0663 against CLW’s running Specn. No. CLW/ES/A-12/D for Roof Surge Arrester ET-2 & CLW Specification No. CLW/ES/3/0016)
...
more...

Attached Images:
SPECIFICATION FOR 42 KV GAPLESS LIGHTNING ARRESTOR(1)
Link: click here
SPECIFICATION FOR 42 KV GAPLESS LIGHTNING ARRESTOR(2)
Link:click here
SPECIFICATION FOR 42 KV GAPLESS LIGHTNING ARRESTOR(3)
Link: click here
All of You can also see these Three Diagrams with details by Clicking on "Download-1", "Download-2","Download-3" and "Download-4" of Item No: 9 of the Following Link of CLW Home Page containing "Draft Specification for Feedback":
CLW Page of Draft Specification for Feedback

Translate to English
Translate to Hindi

2 Posts

3740 views
3

Sep 12 2015 (20:13)
indian railways   7174 blog posts
Re# 1588816-3              
Driver's manual for WAG9 (applicable for P5 & P7 too) : click here
Translate to English
Translate to Hindi

3767 views
3

Sep 12 2015 (20:30)
indian railways   7174 blog posts
Re# 1588816-4               Past Edits
Latest developments in 3-phase locos (as per the manual) :-
*************
1. The existing GTO based traction converter is a group drive, i.e., all the traction motors in a bogie are connected in parallel. While, the IGBT based
converter has got single axle drive capability, therefore, in case of any
problem
...
more...
with a particular TM, only that particular TM can be isolated unlike in
the GTO based converter where the whole bogie has to be isolated.
2. Due to single axle drive it has got better adhesion performance.
3. Because of smaller size of the converter it may be possible to install
additional equipments like hotel load converter in the locomotive.
4. In order to improve the control of the drive, the active type speed sensors
have been provided which have better resolution by incorporating sensors
which can provide strong signals at 200 pulse per revolution.
5. This converter has taken full advantage of the advancement in the processor
speed which has paved the way for less number of PCB cards with better
performance at the higher temperatures.
6. Power loss reduction by approx. 50% in comparison with GTO loco
equipment.
7. Annual energy saving (considering @ Rs 4.62 / unit) will be approx. Rs. 34
lakhs assuming loco utilization of 85% service per day.
8. 40% reduction in weight and compact in size compared to GTO equipment.
9. 60% reduction in usage of electric cards (only 3 major cards compared to
17), hence increasing the loco reliability.
10. Sensor less speed control.
11. Water cooled system thus safer vis-à-vis oil cooled system.
12. Better slip / slide controls, because of axle control and modern high speed
digital signal processing algorithm.
13. Less harmonics because of high switching frequency.
14. Designed without using any proprietary ASIC.
15. Configured to open standard controls TCN based network.
16. Modern design of software using Matlab / Simulink.

Translate to English
Translate to Hindi

4041 views
3

Sep 12 2015 (20:39)
guest   6387 blog posts
Re# 1588816-5               Past Edits
The IGBT system is much more advanced as because you can isolate and repair the malfunctioning TM easily if break down occurs for IGBT failure. You don't need to isolate the particular BOGIE like GTO which is much more complex. I have already shared the Link of IGBT Loco Outturn from CLW which shows that so far 80% of the Loco turned out by CLW are of IGBT Locos.