Travel Question
4094 views
0

Sep 16 2016 (18:18)  
 
guest   157 blog posts
Entry# 1993557              
how to start a wap-5 locomotive?
Translate to English
Translate to Hindi

4 Posts

2250 views
0

Sep 16 2016 (18:31)
guest   157 blog posts
Re# 1993557-5              
bhai ' mr.Finally DBRT Raj will join GANG^~' ne kaha tha .
Translate to English
Translate to Hindi

1616 views
1

Sep 16 2016 (18:33)
Subrat Shrivastava   29709 blog posts
Re# 1993557-6              
The process is nearly same but not too right to start a wap5.
This is the general procedure for starting a locomotive of the WAM-4, WAP-4, WAG-5, or WAG-7 class.
Compare to the WDM-2 diesel locomotive starting procedure.
Ascertain that A9 and SA9 cocks in non-driving cab are shut and those in the driving cab are open.
Ascertain
...
more...
that A8 / BP charging cock is in open position.
Ascertain that MU2B is in the lead position.
Enter cab two and put HBA on position one, depress ZUBA and check voltage in UBA. It should register 110 volts DC
Enter cab one and put ZVPA on position one. The 'baby' compressor comes to life. The 'baby' compressor should be run till pressure in ER pressure goes up to 8.0 kg/cm^2
BL key should be unlocked and it should be ascertained that LSDJ, LSCHBA, LSGR and LSB pilot lamps are glowing.
ZPT should be inserted and put on position one or two depending on pantograph to be raised. Ascertain that the pantograph has been raised.
To close the DJ BLDJ should be closed and BLRDJ should be depressed and kept depressed for four seconds or until LSDJ extinguishes (whichever is earlier).
THE LOCO IS NOW ENERGIZED.
BLCP should now be switched on and MCP running should be ascertained. MR pressure should be built up to 10 kg/cm^2.
It should be ascertained that the MCP cuts in at 8.5 kg/cm^2 pressure and cuts out at 10 kg/cm^2.
Ascertain that BP pressure is 5 kg/cm^2 and HS valve pressure is in the range of 1.4 to 1.7 kg/cm^2.
SA9 should be operated and it should be ascertained that the BC gauge reads a pressure of 3.5 kg/cm^2.
In case of a vacuum-braked rake BLPV should be switched on and the vacuum allowed to build up.
BLMVT should next be switched on and it should be ascertained that after five seconds MVRH MVMT 1/2 have come to life.
Exhauster lubrication should be checked.
In case of SLM mechanical exhauster oil feed rate for the bearing should be set at twelve drops per minute; for floating ring at eight drops per minute; and at three drops per minute for a Nordy type exhauster.

Translate to English
Translate to Hindi

1469 views
0

Sep 16 2016 (18:34)
Subrat Shrivastava   29709 blog posts
Re# 1993557-7              
vo mazaak kar raha hai
Translate to English
Translate to Hindi

1559 views
0

Sep 16 2016 (18:39)guest
Re# 1993557-8              
majaak tha..waise ye janne ke liye apko loco pilot banna padega wo bhi 3 phase wala...
Translate to English
Translate to Hindi

2278 views
0

Sep 16 2016 (18:44)
guest   157 blog posts
Re# 1993557-9              
@1993557-8  @guest
i know mr.
Translate to English
Translate to Hindi