May 08 2012 (12:54) HDC/Harishdadpur P.H. (1 PFs)
soumitra.chawathe^~
soumitra.chawathe^~ 34403 blog postsCan anyone please elaborate what is the meaning of P.H. / HDC in the station name?
18 Posts
is the SSP written on transformer when we reach near to a station ?
hey it is like this thing once i passed thru samalpatti stn in TN and near the station it had the transformer like thing with a board samalpatti s.s.p
Sectioning and Paralleling:
************************
The portion of the OHE between a feeding post and the next neutral zone on one side is called a section of the traction supply. A substation normally supplies power to two sections, these sections consisting of the up and down OHE portions between the feeding post and the neutral section on either side. A sectioning and paralleling post (SP) (or sometimes sectioning post) is provided near the neutral zone, that has two paralleling interruptors to keep the two portions of the OHE (one in each direction) supplied...
more...
************************
The portion of the OHE between a feeding post and the next neutral zone on one side is called a section of the traction supply. A substation normally supplies power to two sections, these sections consisting of the up and down OHE portions between the feeding post and the neutral section on either side. A sectioning and paralleling post (SP) (or sometimes sectioning post) is provided near the neutral zone, that has two paralleling interruptors to keep the two portions of the OHE (one in each direction) supplied...
more...